Contact Us

Contact Person : Daisy

Phone Number : 86-13425728677

WhatsApp : +8613425728677

Free call

420m3/h Central Air Conditioning Unit Kuwait Window Mount Fcu Cassette Type

Minimum Order Quantity : 1 unit Price : 1000USD-5000USD/unit
Packaging Details : standard pallet packing Delivery Time : 30-60days
Payment Terms : L/C, T/T, Western Union Supply Ability : 50 Containers Per Month
Place of Origin: CHINA Brand Name: VENTECH
Certification: CE Model Number: Horizontal Concealed Fan Coil Units

Detail Information

Product Name: Horizontal Concealed Fan Coil Units Price Term: FOB
Certificate: CE Warranty: 2 Years After Date Of Shipment
Operating Voltage: Depends On The Country Mounting: Floor Standing, Wall / Window Mount, Ceiling Mount, Split, Rooftop Mounted
Sample: Yes Busiess Type: Factory
High Light:

420m3/h Central Air Conditioning Unit

,

Kuwait Central Air Conditioning Unit

,

Window Mount Ceiling Cassette FCU

Product Description

VENTECH(Vcare) central air conditioner kuwait Ceiling cassette FCU Fan coil Units HVAC system

 

 

Model FP200KM4 FP300KM4 FP400KM4 FP500KM4 FP600KM4 FP800KM4 FP1000
KM4-Q
FP1200KM4 FP1400KM4
Air volume Q H m3/h 360 510 680 850 1020 1360 1700 2040 2380
M 250 420 560 650 780 1050 1310 1570 1830
L 200 350 460 520 600 800 1010 1210 1410
Z H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M 280 390 520 650 785 1030 1380 1530 1980
L 230 300 400 500 605 860 1060 1170 1650
Cooling capacity Q H W 2000 2710 3620 4530 5440 7200 9100 10500 12500
M 1700 2410 3100 3830 4485 6000 7050 8560 10500
L 1500 2140 2750 3360 3500 4500 5500 6710 8450
Z H W 1750 2620 3500 4370 5400 7000 8750 10500 12150
M 1410 2250 2920 3645 4440 5890 7340 8800 10130
L 1020 1860 2430 3040 3745 4900 6110 7260 8450
Heating capacity Q H W 3000 4070 5440 6800 8160 10800 13700 16000 18600
M 2810 3520 4650 5750 6700 9350 10600 13700 15260
L 2480 3150 4130 5100 5200 7690 8300 11200 12700
Z H W 2770 4130 5250 6750 8100 10500 13120 15730 17500
M 1990 3010 4370 5460 6450 8750 10940 12530 14580
L 1310 2530 3645 4370 5190 7290 8990 10920 12150
Noise level Q ≤dB(A) ≤dB(A) 37 39 41 43 45 46 48 50 52
Z ≤dB(A) ≤dB(A) 37 39 41 43 45 46 47 50 52
Power source V/Ph/Hz V/Ph/Hz 220-240V/1/50Hz
Motor Q Input W 46 52 70 80 93 130 150 231 268
Z Input W $32 36 36 60 66 90 124 180 225
Heat exchanger Type   Copper pipe with aluminum fins
Q
cooling
Water flow m3/h 0.31 0.48 0.65 0.81 0.98 1.28 1.65 1.99 2.26
WPD kPa 10 18 22 28 37 35 30 35 50
Q
heating
Water flow m3/h 0.31 0.48 0.65 0.81 0.98 1.28 1.65 1.99 2.26
WPD kPa 10 18 22 28 37 35 30 35 50
Z
cooling
Water flow m3/h 0.3 0.46 0.63 0.79 0.96 1 26 1.63 1.97 2.24
WPD kPa 30 30 30 30 40 40 40 40 50
Z
heating
Water flow m3/h 0.3 0. 46 0.63 0.79 0.96 1.26 1.63 1.97 2. 24
WPD kPa 30 30 30 30 40 40 40 40 50
Max working pressure MPa 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
Dimension Q Length mm 650 650 650 850 850 850 1050 1050 1050
Z mm 620 620 790 790 1040 1140 1140 1140 1140
Q Width mm 650 650 650 850 850 850 1050 1050 1050
Z mm 620 620 790 790 790 790 990 990 990
Q Height mm 278 278 318 318 318 318 318 318 318
Z mm 430 430 430 430 430 430 430 430 430
Unit net weight Q kg 26 26 28 34 34 36 50 50 50
Z kg 27 27 32 32 37 39 49 49 49
 

 

  • Unique Configurations - If your application requires a physical configuration that is different, VENTECH can accommodate individual needs. The cover photo shows a special workstation arrangement required by a machine tool manufacturer for cooling a high-speed spindle. Other unique configurations include designs to fit inside the customer's system.
  • Special Controls - Chiller units can be controlled in unique ways. Remote sensors can monitor process parameters and control the cooling to make the process operate in the optimum manner. Remote controls allow placement of chillers in distant locations, whereas the controls can remain in a more convenient place.
  • Special Electrical Specifications - Explosion-proof electrics are necessary for situations where the chiller must operate in hazardous atmospheres. Where hazardous conditions always exist, special electricals are mandated. When the hazardous conditions do not always exist , purged or pressurized electrical enclosures offer the required safety at reasonable cost. Unusual electrical specification can include uncommon voltages, sealed systems for
  • Special Pumps - Self-priming pumps or pumps of unusual metallurgy can be specified; or pumps can be fitted with special motors or impellers to provide high pressure or high flow.
  • Special Temperatures - Virtually any temperature range that you can envision can be accommodated.
  • Dual Refrigeration Systems - Two complete refrigeration systems (dual compressors) can be fitted for those applications with widely varying loads or where redundancy (back-up) is important.
  • Standard Options - More easily produced than a custom chiller, a standard VENTCH chiller can incorporate any of the following options at modest cost: Special paints and colors. Outdoor installation packages Special temperature controllers, digital or analog Special instrumentation. Mounting clips or casters. Remote switching. Large/small tanks. No tank - arranged for once-through cooling. Additional safety switches: low flow, low temperature, high temperature, low water pressure, etc.
  • A wide range of capacities in custom-designed chillers for specialized cooling
  • Air and Water Condensing Models
  • Special Options on Standard Models
  • Models with Modified Systems, Special Components or Controls
  • Total Custom Engineering

Want to learn more about Vcare Wholehouse air conditioner,please contact us by email directly.

Email:karen@chinaventech.com

Tel:0086 13620119598

 

 

 

 

 

You Might Be Into These
Get in touch with us

Enter Your Message

sales@chinaventech.com
+8613425728677
86-13425728677