380V 51.3kW 10600m3/h Rooftop Air Conditioning Unit

Minimum Order Quantity : 1 unit Price : 1000USD-5000USD/unit
Packaging Details : standard pallet packing Delivery Time : 30-60days
Payment Terms : L/C, T/T, Western Union Supply Ability : 50 Containers Per Month
Place of Origin: CHINA Brand Name: VENTECH
Certification: CE Model Number: Rooftop air conditioning unit

Detail Information

Product Name: Rooftop Air Conditioning Unit Condition: New
After-sales Service Provided: Engineers Available To Service Machinery Overseas, Video Technical Support, Field Installation, Commissioning And Training, Online Support Price Term: FOB/EXW
Power: Depends On The Country Use: Project/Office/Commercial Area
Type: Commericial Air Conditioner
High Light:

10600m3/h Rooftop Air Conditioning Unit

,

51.3kW Rooftop Air Conditioning Unit

Product Description

Air conditioning unit central air conditioner scrap value Rooftop air conditioning unit commericial air conditioner

VENTECH(Vcare) Split type Rooftop Air Conditioning Unit (fresh air)

 

Important Factors for Choosing Central AC

Size
A synonym for the air conditioner’s cooling capacity, size is measured in British thermal units per hour (Btu/hr.) or in “tons.” One ton of cooling equals 12,000 Btu/hr.For sizing guidance, check our VENTECH(Vcare) type.

Efficiency
This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.

Maintenance
Central AC systems need regular maintenance for optimal performance. When you negotiate your installation, it's worth negotiating a service plan that combines regular inspections with discounts on repairs and a labor warranty into the overall price. Prices for such a service can vary widely.

Programmable thermostats
Setting your smart or programmable thermostat at the right temperature can reduce your cooling costs by about 10 percent. The right temperature varies on your comfort level, but start by setting it at 78° F and experiment until you find the sweet spot. You’ll save about 3 percent on your utility bill for every degree you raise the set temperature for your central air, according to the Department of Energy. And keep in mind that using a box or ceiling fan, which costs little to run, can make you feel 3° F to 4° F cooler.

 

 

 

Cooling,Heat pump, Electrical heating Data

 

Parameter Cooling capacity Heating capacity Air flow (m3/h) ESP Consumed power (kW) Noise
≤dB(A)
Dimension Weight (Kg)
Model kW kW (Pa) Cooling Heating L(mm) W(mm) H(mm)
VWD-22D 21.5 22.6 4900 150 8 08 15.37 62 2800 1100 1200 510
360 8.52 15.81 61
VWD-30D 29.4 30.9 6000 150 9.85 17.11 63 2800 1100 1200 530
350 10.69 17.88 62
VWD-34D 33.6 35.4 7100 200 13.25 22.58 64 2950 1700 1250 860
400 13.25 22.58 64
VWD-44D 43.5 45.8 9100 200 17.74 29.08 67 2960 1700 1250 960
400 17.74 29.08 66
VWD-52D 51.3 54 10600 200 18.2 29.26 69 2950 1700 1250 1230
400 19.4 30.36 68
VWD-58D 58.1 61.2 11000 200 20.5 35.31 70 3450 1000 1450 1250
400 20.5 35.31 70
VWD-62D 62.3 65.6 12000 200 23.9 39-16 72 3450 1800 1450 1285
500 25 40.26 71
VWD-66D 66.1 69 13000 200 26.06 43 08 73 3450 1800 1450 1310
500 27.71 44.73 72
VWD-69D 68.6 72.2 14000 200 30.73 49.7 76 3450 1800 1450 1400
500 32.93 51.9 75
VWD-88D 87.6 92.1 16000 300 30.2 52 42 76 4775 1800 1700 1735
500 32.4 51.9 76
VWD-1000 99.5 104.8 16800 300 38.54 63.24 77 4775 1800 1700 1820
500 40.74 65.44 77
VWD-1150 114.8 120.9 21000 300 45.92 76.09 78 4650 1800 2230 2265
560 45.92 76 09 77
VWD-1240 123.9 130.5 22000 300 50.39 81 78 4650 1800 2230 2340
560 S4.24 84.45 78
VWD-1330 133.1 140.2 23500 350 54.06 85 04 79 4650 1800 2230 2420
560 57.91 88 89 79
VWD-1450 143 8 161.4 25000 360 62.3 100.32 80 4650 1800 2230 2510
550 62.3 100.32 79
WVD-172D 171.3 180.4 28000 400 68 61 107.26 81 6000 2250 2340 3245
600 73.01 111.66 80
VWD-181D 180.2 189.8 29000 400 73.48 112.61 81 6000 2250 2340 3380
600 77.88 117.01 81
VWD-190D 189.8 199.9 30000 400 81.55 127.65 82 6000 2250 2340 3520
600 81.55 127.65 81
VWD-1990 199.1 209.7 31000 400 85 22 131.69 83 6000 2250 2340 3590
660 85 22 131.69 82

 

*Evaporator and condenser are using with copper aluminium fin.

*Temperature controlling range is 16-30℃,temperature controlling accuracy is ± 2℃

*Electrical heating is finned type stainless steel electrical heating.

*Power consumpting includes the summation of heat pump heating and auxillary electric heating.

*Connecting type of cooper is soldering.

*The type of power is 380V/3N-50Hz.

*Refrigerant: R22.If the refrigerant is R407c.the parameter is ditto.

 