Contact Us

Contact Person : Daisy

Phone Number : 86-13425728677

WhatsApp : +8613425728677

Free call

Air conditioning unit eer central air conditioner Horizontal Concealed Fan Coil Units

Minimum Order Quantity : 1 unit Price : 1000USD-5000USD/unit
Packaging Details : standard pallet packing Delivery Time : 30-60days
Payment Terms : L/C, T/T, Western Union Supply Ability : 50 Containers Per Month
Place of Origin: CHINA Brand Name: VENTECH
Certification: CE Model Number: Horizontal Concealed Fan Coil Units

Detail Information

Product Name: Horizontal Concealed Fan Coil Units Payment Term: TT,LC
Working Pressure: Different Working Pressure Retun Air: DB 27℃/WB 19.5℃
Standard: International Standard Lead Time: 30 Days After Receiving Prepayment
Warranty: 2 Years After Date Of Shipment Feature: Adjustable

Product Description

VENTECH(Vcare) Air Conditioning Unit Central Air Conditioner Horizontal Concealed Fan Coil Units

Horizontal Concealed FCU specification table       Vertical coil three pipes system                  
Model FP WA*-3* 200 300 400 500 600 700 800 1000 1200 1400
Air volume H m3/h 340 510 680 850 1020 1200 1360 1700 2040 2380
M 280 380 515 660 705 910 1040 1280 1560 1800
L 1B0 260 340 430 530 610 710 860 1060 1190
Cooling capacity H W 2020 3010 3700 4560 5600 6400 7600 9000 10800 12600
M 1683 2742 3000 3716 4424 5630 6435 7470 9296 10623
L 1561 2293 2479 2921 3793 4905 5606 7200 8543 8820
Heating capacity H W 3500 5300 6700 8200 10100 10940 13500 15000 18900 20000
M 2526 3533 5153 5954 7099 8057 9906 11560 15163 18600
L 1682 2321 3449 4258 4833 S558 6774 7500 10085 14240
Motor Input power(H) Normal ESP (12Pa) W 37 52 62 76 96 113 134 152 189 228
High ESP (30Pa) 44 69 72 87 108 134 156 174 212 253
Super High ESP
(50Pa)
49 66 84 100 118 158 174 210 250 300
Heat exchanger (3-pipe) Cooling/
Heating
Water flow m3/h 0.367 0.517 0.638 0 796 0.978 1.128 1.371 1.516 1 822 2.152
Water drop pressure kPa 17 22 18 20 30 20 30 30 30 40
Noise H Normal ESP (12Pa) dB(A) ≤37 ≤39 ≤41 ≤43 ≤45 ≤47 ≤46 ≤48 ≤50 ≤52
High ESP (30Pa) ≤40 ≤42 ≤44 ≤46 ≤47 ≤49 ≤48 ≤50 ≤52 ≤54
Super High ESP
(50Pa)
≤42 ≤44 ≤46 ≤47 ≤49 ≤51 ≤50 ≤52 ≤54 ≤56
Dimension Length mm 655 785 885 945 1065 1185 1405 1525 1725 1925
Width 496 466 466 466 466 466 466 466 466 466
Height 243 243 243 243 243 243 243 243 243 243
Unit weight No return air box KG 12 14 16 17 18 19 26 29 32 35
 

 

*Cold water cooling condition: return air :DB 27℃/WB 19.5℃; fresh air DB35℃/WB28℃;cold water inlet/outlet 7℃/12℃.

*Heat water cooling condition: return air :DB 15℃/fresh air DB 7℃;inlet/outlet water: 60℃/50℃.

*Heating retur air condition: DB 15℃,fresh air:DB 7 ℃/vapor inlet:115℃,pressure:0.2Mpa.

 

Air Handling Unit (AHU) – You may have heard this phrase before. The air handling unit is the furnace where the air is conditioned for temperature and humidity. It is then circulated through the ducts to the rooms. The central air conditioner typically provides both cooling and heating features.

Since the central AC is meant to cool the entire house, the capacity of the central AC system is based on the square feet area that needs cooling. Based on the climate, there are reference numbers for the cooling capacity (BTU per hour per square feet, tons per thousand square feet, kW per thousand square feet). It is advisable to have a system with some buffer capacity (15-20% higher than calculated) to take care of the efficiency decrease over time.

Digital or rotary thermostats are provided in each room for room-specific temperature control. This helps in the formation of temperature “zones” in the house, based on the temperature requirement of the occupants of the room.

 

 

Want to learn more about Vcare Wholehouse air conditioner,please contact us by email directly.

Email:karen@chinaventech.com

Tel:0086 13620119598

 

 

 

 

 

You Might Be Into These
Get in touch with us

Enter Your Message

sales@chinaventech.com
+8613425728677
86-13425728677